Inspection and Start-up checklist
Handling and Installation
Unit mounted on solid level surface
Sufficient space allowed for access to unit and accessories
Proper electrical service provided
Hot water provided to humidifier
Drain line is installed with proper pitch
Ductwork, fittings and grilles installed properly
All cold duct surfaces insulated
No obstructions to air flow
Unit startup
General visual inspection
All wiring connections checked
All ducts, grilles and panels in place
Start unit
Check connections for air leaks and water leaks
Check for excessive noise or vibration
Check for operation of humidifier
Maintenance
General
CAUTION
Before performing maintenance on the unit, read and understand the safety information
contained in this guide.
The Wine Guardian is designed for minimum maintenance. Never oil any part of the humidifier.
Always disconnect the electrical power to the humidifier and the cooling unit if used.
A regular maintenance program prolongs the life of the humidifier and maintains the humidity in
the cellar. Frequency of cleaning and replacement of the drip pad depends on the inlet water
conditions and the cleanliness of the cellar air. The drain system may also trap dust and dirt.
When water no longer stays on the pad or mineral build-up has started to reduce airflow, the pad
needs to be replaced.
Suggested maintenance schedule:
Monthly – may change to quarterly depending on experience with individual cellar
Check drain – clean if needed – confirm steady flow of water while in operation
Check for noise or vibration